Operating InstructionsnEnglish Version PowadorXP200-HV TLXP250-HV TLXP350-HV TL
Unit descriptionPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENComponents inside the right cabinet109871332465AA BBA–A
Technical dataOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page Technical data. Electrical dataInput levels XP200-H
Technical dataPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN. Mechanical dataXP200-HV TL XP250-HV TL XP350-HV TLDi
Transportation and DeliveryOperating Instructions Powador XP200-HV TL, XP250-HV TL, XP350-HV TL_EN Page 135 Transportation and Delivery5.1 DeliveryT
Transportation and DeliveryPage 14 Operating Instructions Powador XP200-HV TL, XP250-HV TL, XP350-HV TL_ENFigure 6: Lifting the inverter5.3 Storage
Mounting the inverterOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page Electrician Mounting the inverter. Selecting
Mounting the inverterPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENElectrician. Preparing the installation siteNOT
Mounting the inverterOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page ElectricianXP-HV TLMeasurand Internal consumpti
InstallationPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENElectrician Installation. Connecting the inverter cabi
InstallationOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page ElectricianFigure : Electrical connection for the cabin
InstallationPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENElectricianGrounding the inverter " Determine the lay-
InstallationOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page ElectricianDANGERLethal voltages may be present in an IT gr
InstallationPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENElectrician. Connecting the PV generator (DC connection)
InstallationOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page Electrician. Connecting the power supplyWithout auxiliar
InstallationPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENElectrician.. Connecting the external power supplyIn th
InstallationOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page Electrician Figure : Connecting the external power s
InstallationPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENElectrician. Connecting the interfacesOverview Fi
InstallationOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page Electrician.. Connecting the digital input/output-UDIO1
InstallationPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENElectrician... S output-UDIO24 V1b 2b 3b 4b5b1a 2a 3a
InstallationOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page Electrician.. Connecting the RS- interfaceThe RS
Operating Instructions Powador XP200-HV TL, XP250-HV TL, XP350-HV TL_EN Page 31 General notes ... 41.1 Abo
InstallationPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENElectrician " A terminating resistor ( , . W,
InstallationOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page Electrician.. Connecting the RS- interfaceThe RS
InstallationPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENElectrician-RS485A(DATA–)B(DATA+)1b 2b 3b 4b1a 2a 3a 4aGNDJ
InstallationOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page Electrician... Solar sensorbaUAIabababSi-TCb
InstallationPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENElectrician.. Connecting the remote power control Remo
InstallationOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page ElectricianFigure : Cabinet, interior view (XP-HV)Ke
InstallationPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENElectricianChecking the circuit breakers on PV side and gri
InstallationOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page ElectricianSelecting the country-specic setting " Pre
User interfacePage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN User interface. User interface (MMI) The MMI has a
User interfaceOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page . MMI menu structureUsed symbols:01234Menu level (0, 1
General notesPage 4 Operating Instructions Powador XP200-HV TL, XP250-HV TL, XP350-HV TL_EN1 General notes1.1 About this documentationWARNINGImprope
User interfacePage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENCountry-specicMenu levelDisplay/ SettingMenu typeAction
User interfaceOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page . MMI main menuONOFFPVgeneratorInverterGridCircuit br
User interfacePage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENSAFERemove the SD card“Data was saved to the SD card” ico
User interfaceOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page .. String monitoringChanges to the conguration for t
User interfacePage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN.. Faults and warningsDisplay current faults and warn
User interfaceOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page .. StatisticsThe statistics function displays the dat
User interfacePage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN.. SettingsChanging settings " Use the “Setup” m
User interfaceOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page ... Date/TimeNOTESet the current date and local time
User interfacePage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN... Language and country settingsNOTEImproper parame
User interfaceOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page ... Performing a software updateIf a software update
General notesOperating Instructions Powador XP200-HV TL, XP250-HV TL, XP350-HV TL_EN Page 51.2.3 Depiction of additional informationNOTEUseful inform
User interfacePage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENCAUTIONSoftware damage due to an interruption of the sync
User interfaceOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page Communication between the MMI and the control unit (XCU)
User interfacePage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN. Parameters.. PvArray parametersParameter Unit Ra
User interfaceOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page .. Grid parametersParameter Unit Range Description Fa
User interfacePage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENParameter Unit Range Description Factory settingsGrid Und
User interfaceOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page RPC mode select – 0 ... 2 Remote power control:• : Disa
User interfacePage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN.. Controller ParametersParameter Unit Range Descript
User interfaceOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page Parameter Unit Range Description Factory settingsUnbalanc
User interfacePage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENParameter Unit Range Description Factory settingsAsynchro
User interfaceOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page Parameter Unit Range Description Factory settingsQ(V) Con
Safety instructionsPage 6 Operating Instructions Powador XP200-HV TL, XP250-HV TL, XP350-HV TL_EN2 Safety instructionsDANGERLethal voltages are still
User interfacePage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENParameter Unit Range Description Factory settingsCOSPHI_
ConfigurationOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page 9 Conguration9.1 Conguring the interfaces9.1.1 Congu
ConfigurationPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENDigitalDI SelectDI SelectRPC Mode SelectPower Meter (kWh
ConfigurationOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page 9.1.2 Conguring the RS485-2 interface (Powador-proLOG)O
ConfigurationPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN. Press the “Set“ button for “Prolog Protocol“ and inpu
ConfigurationOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page 9.1.5 Conguring the remote power controlONOFFPVgenerato
ConfigurationPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN9.2 Medium voltage guidelineDEMSp.Country-specic functio
ConfigurationOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page Power controlDescription Relative parametersFixed cosphi
ConfigurationPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENTransition between RPC mode and internal modeInternal Mode
ConfigurationOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page Conguring Fixed QRPCDisable RPCFixed cosphiFixed QCharact
Unit descriptionOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page 3 Unit description3.1 Dimensions8702120501970Figure 1:
ConfigurationPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN9.3 Temperature dependent power deratingT176°CkWTT7060501
ConfigurationOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page 9.4.1 Conguring the Powador WebONOFFPVgeneratorInverter
ConfigurationPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENPowador WebSMTP IP Address ...Enable Interval
ConfigurationOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page Powador WebSerial Number SNSender AddressXp-logger@
ConfigurationPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENUser CongurationBuzzer on FaultsBuzzer on WarningsService
ConfigurationOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page Individual ServerSerial NumberSender AddressReceiver Addre
OperationPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN10 Operation10.1 Starting up the inverterStarting up the inv
OperationOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page 10.2 Operating statesFaultDisconnected, system stopConnect th
OperationPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENOperatingStateRequirements/Actions ResultDisconnec-ted State p
Maintenance/CleaningOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page 11 Maintenance/CleaningMaintenance must be perform
Unit descriptionPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN3.2 Overview circuit diagramPVModules 450 ... 830 V DCI
Maintenance/CleaningPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENRecommended maintenance intervalsMaintenance work
Maintenance/CleaningOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page 11.2 Cleaning and replacing the fansThe inverter i
Maintenance/CleaningPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN " Switch o the inverter (see section on p
Faults and WarningsOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page Replacing the outlet lter (Figure 73). On the ins
Faults and WarningsPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_ENMessage Code DescriptionCabinet Under Temp. Warning
Faults and WarningsOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page Message Code DescriptionGrid Over Frequency F32 Over
ServicePage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN13 ServiceWe place special emphasis on the quality and longevit
Decommissioning/DismantlingOperating Instructions Powador XP200-HV TL, XP250-HV TL, XP350-HV TL_EN Page 87Electrician14 Decommissioning/DismantlingDA
EU Declaration of ConformityPage Operating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN16 EU Declaration of ConformityManufacture
Unit descriptionOperating Instructions Powador XP-HV TL, XP-HV TL, XP-HV TL_EN Page 3.3 Components inside the inverterThe inverter componen
Carl-Zeiss-Straße 1 · 74172 Neckarsulm · Germany · Fon +49 7132 3818-0 · Fax +49 7132 3818-703 · [email protected] · www.kaco-newenergy.de3003115
Commentaires sur ces manuels